Main service disconnect
On the service entrance switch or main breaker, with the system voltage and rating.
ElectricalCECCSA Z462
Service, disconnect, transformer and capacitor warnings, plus the conductor and fuse tags an inspector looks for. Danger and warning plates for hazards, black and white for equipment ID.
On the service entrance switch or main breaker, with the system voltage and rating.
Where the main disconnect is out of sight, so firefighters and electricians can find it.
Isolating switches and bolted disconnects that are not rated to break load current.
Power factor correction and harmonic filter capacitor enclosures.
Doors to transformer vaults and rooms with liquid-filled or dry-type units.
A long, low strip above a row of panels or a switchboard line-up.
Covers and doors over terminals that stay live, adhesive back.
Motor terminal boxes, control enclosures and luminaires that must be dead before work.
Inside dead-front doors and on barriers over bus that is live when the cover is off.
Current transformer and metering cabinets sealed by the utility.
Beside a portable generator inlet with a breaker interlock.
Service equipment and switchboards, with the calculated value and the date it was worked out.
Inside fused switches, so the right class and rating goes back in.
Neutral bars and neutral conductors in switchboards and splitters.
At the grounding electrode clamp and where the grounding conductor lands in the service.
Bus bars, feeders and terminations of phase A, in red to the CEC colour code (B black, C blue).
Panelboards and switchboards protected by a series-rated breaker combination, so only identical breakers go back in.
Buildings with two service disconnects; order a 2 OF 2 plate for the other one.
Building mains and sub-mains that look like service equipment but are fed from another disconnect.
At each service and on equipment fed from more than one utility service.
Substations, switchgear and transformers on the owner's side of the utility demarcation.
Disconnects and breakers whose load conductors can be backfed by a generator, UPS, PV system or another feeder.
Water pipe, gas pipe and main bonding jumpers, so they stay on through plumbing and meter work.
Above or on ground rod test wells, numbered to match the grounding drawing.
Beside baseboard, unit and duct heaters that run hot enough to burn and must not be covered.
Breakers and switches with a shunt trip, so whoever finds one open checks the remote trip before resetting.
Equipment and feeders, with the largest breaker or fuse the conductors and nameplate allow.
At the service when the revenue meter is in another room, for meter readers and utility crews.
Doors to switchgear rooms, vaults and fenced electrical yards, the most-ordered high voltage sign.
On enclosures, bus ducts and equipment that the public or other trades can reach.
Switchboards, transformers and control cabinets where the full consequence has to be spelled out.
Electrical closets, control rooms and equipment enclosures that only trained staff should open.
Covers on control boxes, drives and power supplies that staff should never open.
Electrical rooms, switchgear and generator rooms, beside the extinguisher.
Construction and renovation sites with energized temporary wiring or open boxes.
Marker posts and fences along underground primary feeders and duct banks on private property.
Yards, lanes and loading areas where trucks, booms and dump boxes pass under service drops or lines.
Dry-type transformers in electrical rooms and on mezzanines, where storage blocks the vents.
Substation fences, poles, towers and structures carrying overhead conductors.
Above panels in storage rooms, garages and warehouses where stock and carts creep in front.
On the insulation jacket of heat-traced pipes and vessels, so nobody cuts into a live cable.
Inside main breakers and service disconnects, where the line terminals stay live with the handle off.
Electrical rooms, substations and work near overhead lines, so only non-conductive ladders are used.
Panels, enclosures and equipment covers on 120/208 V three-phase systems.
Residential and small commercial panels and equipment on single-phase 120/240 V service.
Switchboards, panels and enclosures on 347/600 V four-wire systems, the common Canadian commercial voltage.
Doors and fences of 13.8 kV switchgear rooms, substations and customer-owned primary equipment.
Doors and fences of 27.6 kV switchgear, transformer rooms and substations, common on Ontario distribution.
Fences and gates of 44 kV substations and customer-owned supply stations.
Food plants and wash bays, on panels, starters and junction boxes in the washdown area.
Service switchboards and MCCs on high-resistance grounded systems, where a first ground fault does not trip.
Switchboards on ungrounded delta systems, so workers check the ground detector before starting.
Build it from scratch in the sign maker, or send the wording through the quote form and we'll draw it for you.
References name the standard the wording usually comes from. Your inspector (the authority having jurisdiction) has the final say on wording, size and colour, so check the drawings or spec before you order.